“IRS increases 1st year depreciation from 50% to 100%” - Download Here

Easy To Use

THE MAIN REASON HEAT AND FANS KILL BED BUGS SO WELL IS BECAUSE THE HEAT PENETRATES EVERYTHING IN THE INFESTED AREA AND ALL BED BUGS DIE QUICKLY AT 120° F

IN ORDER TO ALLOW THE HEAT TO PENETRATE ANYWHERE BED BUGS MIGHT BE HIDING YOU NEED TO CREATE ENOUGH SPACE SO THE HOT AIR CAN PENETRATE FURNITURE, APPLIANCES, CLOTHING, WALL HANGINGS, ETC.

  1. COVER ALL VENTS AND WINDOWS WITH PLASTIC SHEETING AND BLUE PAINTERS TAPE – NO AIR GETS IN, NO AIR GETS OUT DURING TREATMENT
  2. MOVE FURNITURE 3 FEET AWAY FROM WALL
  3. SEPARATE CLOTHES ON HANGERS, REMOVE SOME AS NEEDED AND DRAPE OVER FURNITURE
  4. LOOSEN CLOTHES IN DRAWERS, REMOVE SOME AS NEEDED AND DRAPE OVER FURNITURE
  5. LEAVE ELECTRONICS IN THE TREATMENT AREA BUT MAKE SURE THEY ARE TURNED OFF AND UNPLUGGED.
  6. REMOVE ANYTHING THAT WILL MELT OR EXPLODE: CRAYONS, CANDLES, COSMETICS, AMMUNITION, FIREWORKS, FIRE EXTINGUISHERS, AEROSOL CANS,ETC. MEDICINES CAN BE PUT IN REFRIGERATOR. A MORE COMPLETE CHECKLIST WILL BE PROVIDED UPON PURCHASE OF EQUIPMENT.
  7. USING FURNACE, BOILER, PTACS, ETC. PREHEAT THE AREA TO MAX TEMPERATURE IDEALLY START PROCESS THE NIGHT BEFORE BUT 2-3 HOURS SHOULD SUFFICE.
  8. PLUG ORANGE HEATER CORD INTO 110/120V STANDARD WALL OUTLET TO ACTIVATE INTERNAL HEATER FAN
  9. MAKE SURE BLACK HEATER SWITCH IS IN OFF POSITION
  10. PLUG BLACK HEATER CORD INTO 240V STOVE, DRYER, GENERATOR OR BREAKER PANEL. CONNECT TWIST-LOCK CONNECTOR AT OTHER END OF BLACK HEATER CORD UNDERNEATH THE AUTOMATIC THERMOSTAT CONTROL PANEL
  11. CONFIRM GREEN LIGHT ON AND TURN BLACK SWITCH ON TO ACTIVATE HEATER ELEMENTS.
  12. PLUG FAN #1 INTO STANDARD 110/120V WALL OUTLET 5-6’ AWAY FROM HEATER AND POINT AIRFLOW TOWARDS BOTTOM OF HEATER. ONLY OPERATES ON HIGH SETTING. LOW SETTING IS DEACTIVATED.
  13. NEVER ALLOW FAN TO DRAW HEAT FROM HEATER INTO IT AS IT WILL OVERHEAT AND DESTROY THE FAN MOTOR WHICH IS NOT COVERED BY WARRANTY
  14. PLUG FAN #2 INTO STANDARD 110/120V WALL OUTLET AND ANGLE AT 45 DEGREES UP TOWARDS CEILING (TO CREATE CONVECTION VORTEX EFFECT)
  15. ONCE TREATMENT AREA REACHES 120°F (90-120 MINUTES) PLACE PLASTIC MILK CRATES OR RISERS IN BETWEEN THE MATTRESS AND BOX SPRING OR LEAN THEM UP AGAINST EACH OTHER IN AN “A” CONFIGURATION.
  16. CONTINUE TREATMENT FOR 3-4 ADDITIONAL HOURS
  17. USING BLACK SWITCH TURN OFF HEATER ELEMENTS
  18. ALLOW INTERNAL HEATER FAN TO RUN FOR 5-10 ADDITIONAL MINUTES WHILE HEATER ELEMENTS COOL DOWN
  19. UNPLUG ORANGE HEATER POWER CORD TO DISCONNECT INTERNAL HEATER FAN
  20. TURN OFF AND UNPLUG EXTERNAL FANS
  21. OPEN WINDOWS AND/OR TURN ON AC TO BRING TEMPERATURE DOWN TO NORMAL
  22. NO MORE BED BUGS!

 

CALL TODAY TO ORDER THE LAST BED BUG HEATER YOU WILL EVER NEED! 970-221-1036